7.1.2 REMOTE CONTROL (by MODEM)
The second accessory of the Remote Control Package is a specially modified
modem. This modem is not a standard modem. It decodes the data
communication from your ThruScan via phone line into a format in order to
monitor by your PC. It is only necessary for connections by the phone lines.
The modem cable to the WTMD should not exceed 10 mts.
7.1.3 REMOTE CONTROL (by CABLE)
Remote Control can be performed without modem by cable (max 100 mts.). For the places where
there is a control observatory room within the area to be controlled. Such as airports, shopping
centres, military premises or jailhouses or military control points, etc.
If more than one WTMD will be observed from one PC than please inform your dealer in advance
for the specific cable and the necessary technical support.
to get the video from REAL-TIME VISUAL PROSECUTION UNIT to TV
7.2 OUTDOOR PACKAGE
For outdoor weather-proof execution please prefer, ThruScan sX-WP. You may buy outdoor
package to use at outdoor temporarily the ThruScan s3/s6/s9/sX/s15-i/sX-i.
7.2.1 RAIN PROTECT SHELTER/HAT
In cases where ThruScan should be used outdoor, a
peculiar “Rain Shelter/Hat” is provided. This shelter is
designed to protect your WTMD from direct rain. Your
unit must not be left outside and it must be placed
back indoor once its outdoor duty is completed. If the
unit is to be operated outside permanently, then
preferably it must be kept in a cabin to protect it from
direct sun rays, wind, and water.
NOTE: WTMD is versatile electronic equipment. Normally, it must be used indoor or to
provide a means of protection. Pls. remember protection class.
NOTE: The main supply cable for you WTMD must be insulated to prevent any short
circuit and connected to your WTMD through the appropriate window on the rain
shelter.
NOTE: Once the cable is passed through the particular hole on the rain shelter after the
drilling, isolation has to be made on that hole to prevent leakage of moisture.
NOTE: The drain hole is placed on one side of the rain shelter and it is symmetrical from
left to right. Thus the shelter should be converted from left to right depending if any
electronic connection is under this drainage hole or if there is another detector
operating in synchronisation next to it.