ThruScan is always operating properly,
Program and sensitivity settings are correctly made,
LED VU display shows minimal interference(environment electromagnetic noise),
Pacing is performed when Green (READY) pacing lights are on,
Operation is realized according to the instructions.
5.1 NORMAL OPERATING MODE
As stated below operating and using ThruScan is extremely easy.
Using the MENU, as stated in Section 4 is very easy for the user;
1. Turn your ThruScan on by pressing the ON-OFF button from the Control Panel ensure that
it has been properly programmed and set up as in section 4 above,
2. Carry out routine functional test (see Section 5.2),
3. If the daily traffic count is to be reset follow 4.1.6 above,
4. Ensure persons only enter the gate way when the green pacing lights are illuminated,
5. Finally if an alarm is generated refer to section 5.3 below.
5.2 ROUTINE TESTS
ThruScan should be tested daily before use and in addition at any time the unit is moved or
against to the environmental changes.
The actual tests undertaken should be carried out to suit the operational requirements of the user,
an example is as follows;
1. Switch on ThruScan ( Press ON-OFF Button),
2. Check the correct Security Level is selected for the required operational risk (see section
4.1.1),
3. A ‘clean tester’ i.e. a person who has no metal objects on, should walk through the gateway
to ensure that no alarm condition is activated. This procedure should be repeated at least 3
times at varying speeds ranging from 0.5 mt/sec. to approximately 1.5 mt/sec.,
4. The ‘clean tester’ should then carry out a series of tests by passing through the gateway
carrying a sample or similar of a target or forbidden item to ensure the item is detected and
the correct alarm condition is generated. This procedure should be repeated several times
with the target item held at different locations on the body e.g. high, middle, low, left, right
& centre etc. On each occasion the target item should be detected and the location
indicated upon both the Graphic Display Panel (see section 3.1.2) and with the Zone-Lights
on side panels, (see section 3.4),
5. The test in 4 above should be repeated with differing size target items as appropriate to the
operational requirements and at varying speeds as above,
6. Should a target item fail to be detected check the Sensitivity Level is correctly set for that
size of object,
7.
Any failure or malfunction should be investigated immediately,
8. Once tests have been completed the Alarm Counter (see section 4.1.5) and the Traffic
Counter (see section 4.1.6) may be reset ready for the day’s operation.
5.3 ALARM STATE
If a person triggers an alarm when passing through the archway, the operator should instruct the
individual to step outside the walk-through and remove any metal objects from their body and/or
clothing. The operator should then either scan the person with a hand-held metal detector
(ThruScan dx/dx-x), or ask the person to re-enter the WTMD.