26
4.1.5 ALARM COUNTER
4.1.5.1 FOR; ThruScan
s3/s6/s9/sX/sX–WP
ThruScan have an internal alarm counter and its memory which will indicate the number of alarms
after reset. This may be displayed from “ALARM COUNTER”.
The alarm memory can be viewed or reset as follows:
1. Press UP&DOWN buttons from the MENU until ALARM
COUNTER sub-MENU option is displayed.
2. LCD will display the number of the counted alarms stored in memory;
3. To reset the counter press SEL(√) button to enter the reset
MENU,
4. Use UP&DOWN buttons to select either N (do not reset) or
Y (reset) the alarm counter,
5. Press SEL(√) button to select and fix the setting.
4.1.5.2
FOR; ThruScan
s15-i/sX-i
ThruScan s15-i / sX-i
counts Alarm and Randomly Generated
Alarms separately (Article. 4.1.15). From Left to Right the Menu
Displays the Alarm – Random Alarm Counters. When required you
can check these counter values by entering ALARM COUNTER Menu.
Counter Values can be displayed in two ways or can be reset to zero.
1. Press UP&DOWN Buttons to find Alarm Counter Menu;
2. LCD Displays Alarm Counter Values when entered into Menu
3. To reset the values, press SEL(√) and Enter Menu.
4. 00 (Do Not Reset), 01 (Reset Only Alarm Counter),
02 (Reset Only Alarm Counter) veya 03 (Reset both Counters) selections can be used by
pressing UP&DOWN Buttons.
5. Press SEL(√) to save your settings.
Press UP&DOWN
buttons and change to the next sub-MENU option or press RUN(X) button to
store the changes and thus return to the normal operating mode.
4.1.6 IN-COMING / OUT-GOING COUNTER (TRAFFIC COUNTS)
4.1.6.1 FOR; ThruScan s3/s6
ThruScan s3/s6 contains a internal counter for transitions from the entrance side. The counter
value is displayed on LCD and thus the number of the passings are being controlled from screen.
Counter can be resetted as follows;
1. Find “COUNTER” sub-MENU on MENU by UP&DOWN buttons.
ALARM COUNTER
000125
ALARM COUNTER
000125
RESET Y<=>N
Y
ALARM COUNTER
00125(00021)
ALARM COUNTER
00125(00021)
ACTIVE = 00