3.6 RELAY CONTACT OUTPUTS (RJ11/12)
Relay contacts (for phone connector) are present on ThruScan (on the side panel or
on the control unit). This feature provides to control and use of peripheral equipment
such as CCTV, Camera, Turnstiles, Gates, etc. .
These contacts; ((RJ11/12) can be used for 24 VDC/2 Amps.)
1- NO (Normally Open)
2- NO (Normally Open)
3- Common
4- Common
5- NC (Normally Closed)
6- NC (Normally Closed)
*** Contact numbers of the socket are coded as they appear on the picture/WTMD from left to
right.
CAUTION! Relay Output does not function with “Real-Time Video Prosecution Unit”
equipped Walk-Through Metal Detectors.
3.7 SYNCHORNIZATION AND REMOTE CONTROL OUTPUTS (RJ11/12)
This socket (for phone connector)*** is for two or more WTMDs to be used in tandem
and/or for remote control by using the direct cable or a modem via phone line. See
Section 6.13 and Section 7.1
1- Transmitter1
2- Transmitter2
5- Ground/Earth (Norm)
6- RS 232
*** Contact numbers of the socket are coded as they appear on the WTMD from left to right.
4. PROGRAMMING & SET UP
Programming and set up is performed as follows after the password is entered by
touch pads:
NOTE: Default Password for all ThruScan WTMDs is “ 0000”.
NOTE: The password should only be known and entered by the authorized personal.
Only one person should hold responsibility for procedures requiring the password. The
operator should only be in charge of operating
ThruScan
and do the security control.